Model Number : JGQ2/1.6-XJ
MOQ : 1 set system
Delivery Time : 15-20days
Storage pressure : 1.6 Mpa
Certification : GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Packaging Details : Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Payment Terms : T/T,L/C
Container capacity : 2 L
Max working pressure : 2.5 Mpa
Brand Name : XINGJIN
Place of Origin : Guangzhou,China
Price : USD480-520/set
Filling density : ≤1150 kg/m3
Supply Ability : 30000set/month
Dimensions : 745×425×42 mm
The Server-Rack Fire Suppression Unit is an innovative automatic fire suppression system independently developed by our company. It is specifically designed for protecting equipment cabinets and enclosures. This unit is also known as a temperature-sensing detection and extinguishing integrated device or a pre-engineered fire extinguishing unit.
The unit integrates the following components into a single, self-contained assembly:
One Server-Rack Fire Suppression Unit can protect a single equipment cabinet or, depending on the configuration, multiple cabinets within a defined enclosure.
The device can be charged with either of the following clean agents:
Both FM200 and Novec 1230 are clean gas extinguishing agents that operate primarily through chemical fire suppression, supplemented by physical cooling effects. They are colourless, odourless, low-toxicity, non-conductive, and leave no residue on protected equipment. They will not cause damage to property or precision facilities. With relatively low extinguishing concentrations, they provide reliable suppression for Class B fires, Class C fires, and electrical fires.
The Server-Rack Fire Suppression Unit incorporates two independent detection methods:
This design eliminates the need for a conventional fire detection system comprising smoke detectors, heat detectors, and a separate fire control panel. Our integrated approach offers the following benefits:
The Server-Rack Fire Suppression Unit is suitable for the following applications:
| Industry / Application | Cabinet / Equipment Type |
|---|---|
| IT & Computer Systems | Server cabinets, data storage racks |
| Telecommunications & Communications | Telecom server cabinets, transmission equipment racks |
| Banking & Finance | Bank equipment control cabinets |
| Industrial & Mechanical | Control cabinets across various industries and sectors |
The Server-Rack Fire Suppression Unit offers two temperature-based activation modes:
When the ambient temperature inside the protected enclosure reaches the rated activation temperature of the glass bulb (standard setting: 68 °C, with other temperature ratings available upon request), the bulb bursts instantly. This opens the agent release port, and the stored gas extinguishing agent is immediately discharged through the nozzle. The agent cools the protected area and suppresses the fire.
When the detection tube is exposed to a heat source and reaches its activation temperature (160 °C ± 10 °C), the pressurised gas inside the tube expands rapidly. The tube then ruptures at the point of highest temperature (the fire origin). This pressure drop activates the storage vessel, and the extinguishing agent is discharged through the rupture point of the tube, providing localised cooling and fire suppression.
| Specification | Size L×W×H (mm) | Volume of Storage Container (L) | Filling Density (kg/m³) | Storage Pressure (MPa) | Max Working Pressure (50 °C; MPa) | Applicable Ambient |
|---|---|---|---|---|---|---|
| JGQ2/1.6-XJ | 745×425×42 | 2 | ≤1150 | 1.6 | 2.5 | 0 °C – 50 °C |
| Outer Diameter | Inner Diameter | Thickness | Fusion Point |
|---|---|---|---|
| Φ6 mm | 4 mm | 1 mm | 160 °C ± 10 °C |
|
|
Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers Images |