Brand Name : XINGJIN
Model Number : WZ-Q/T-QZ3-XJ60
Certification : GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Place of Origin : Guangzhou,China
MOQ : 5 set
Price : USD265-296/set
Payment Terms : T/T, L/C
Supply Ability : 30000set/month
Delivery Time : 15-20days
Packaging Details : Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Type : Fm200 direct type/ indirect type
Capacity of agent : 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure : 2.5Mpa
Max working pressure : 4.2Mpa
Working temperature : 0-50℃
Density of unit volume : 0.7kg/m3
Length of detecting tube : 5m-25m
Length of releasing tube : 0.5m-1.5m
Temperature-sensing, self-actuating fire extinguishing devices are an advanced fire suppression solution developed both domestically and internationally. They are fixed, non-electric, and self-actuating, requiring no power source or traditional fire detection and alarm equipment. The entire system consists solely of a fire extinguishing agent storage cylinder and a flexible fire detection tube. The fire detection tube integrates fire detection, device activation, and fire extinguishing agent release. These flexible tubes can be conveniently positioned closest to any potential ignition source. In the event of a fire, the tube ruptures due to heat, instantly releasing the extinguishing agent for targeted suppression.
Automatic fire extinguishing systems with fire detector tubes can be divided into direct and indirect fire detector tube systems based on their system structure.
The system primarily consists of a container containing fire extinguishing agent, a container valve, a pressurized fire detector tube that releases the agent and has fire detection capabilities, a pressure gauge, a check valve, a pressure switch, an alarm, and a dedicated connector for the fire detector tube.
The fire detector tube is a high-tech non-metallic composite product. It combines long-term leak resistance, flexibility, and effective temperature sensitivity. After pressurization, it ruptures within a certain temperature range to release the extinguishing agent or transmit a fire signal.
The fire detector tube is connected to the fire extinguishing agent container via a container valve and is positioned above the most likely fire source to detect it. When a fire occurs, the fire detector tube softens and ruptures at the highest point of heat exposure. The pressure drop in the tube activates the container valve, releasing the fire extinguishing agent through the rupture hole in the fire detector tube to extinguish the fire. At the same time, an alarm bell sounds, alerting the user that the system has been activated. The user must then verify the extinguishing process, repair the system, and refill the extinguishing agent.
This device primarily consists of a container containing the extinguishing agent, a container valve, a pressurized fire detection tube, a release tube, a nozzle, a pressure gauge, a check valve, a pressure switch, an alarm bell, and a dedicated connector for the fire detection tube.
The fire detection tube is connected to the extinguishing agent container via the container valve and positioned above the most likely fire source to detect it. Upon encountering a fire, the fire detection tube softens and ruptures at the highest point of heat exposure. The pressure drop in the tube activates the container valve, releasing the extinguishing agent through the release tube to the nozzle, extinguishing the fire. At the same time, an alarm bell sounds, alerting the user that the system has been activated. The user must then verify the extinguishing process, repair the system, and refill the extinguishing agent.
The temperature-sensing automatic fire extinguishing system solves the long-standing fire prevention problem in fire-prone spaces such as electrical equipment, control boxes, and distribution boards—a challenge that has long affected the fire protection industry. Currently, this system has been widely used in power plants, telecommunications, broadcasting, petrochemical, and railway systems in China, accumulating a wealth of successful experience.
Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes can be used to extinguish the following fires:
Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes must not be used to extinguish the following fires:
The Inert Gas Fire Suppression System will be carefully packaged to ensure safe delivery and handling. Packaging materials include:
We offer worldwide shipping for our Inert Gas Fire Suppression System. All shipments are sent using a reliable and trusted courier service to ensure timely and secure delivery. Customers will receive a tracking number via email once their order has been shipped.
If there are any special handling instructions for your shipment, please contact us at least 24 hours before your order is shipped. We will do our best to accommodate your request.
|
|
Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for Cable Tunnel Protection with 2.5Mpa Working Pressure Images |