Brand Name : XINGJIN
Model Number : FHF
Certification : GSG\TUV\GB6653-2008
Place of Origin : Guangzhou,China
MOQ : 10 set system
Price : Pricing based on quantity
Payment Terms : T/T, L/C
Supply Ability : 30000set/month
Delivery Time : 15-20days
Packaging Details : Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
State : normally open
Model : FHF-W;FHF-W-K;FHF-WS-FK;FHF-WSDc-K;FHF-WSDc-FK;FHF-WSDc-K etc.
Fuse operating temperature : 70 ℃/150 ℃
Operation method : Manual, electric, fully automatic
Shape : Circle, Rectangle
Size : Customizable
Material : Stainless steel 304/201/aluminum alloy, customizable
Power supply : DV24
A fire damper is a device installed on the supply and return air ducts of ventilation and air conditioning systems. It normally remains in an open state, but when a fire occurs and the gas in the duct reaches 70 ℃, it closes automatically. Within a defined period, it satisfies the requirements for fire resistance stability and integrity, providing smoke isolation and fire prevention. The range includes gravity fire dampers, fire control valves, fireproof vents, airtight fire dampers, smoke dampers, electronic self-control smoke dampers, and other variants.
| Product Name | Model + Function Code | Function | Picture |
|---|---|---|---|
| Self-weight fire damper | FHF-W | Normally open; the fuse operates at 70 ℃ / 150 ℃, and the valve automatically closes under blade gravity or spring force. | ![]() |
| Smoke and fire damper | FHF-W-K | Normally open; when the fuse activates at 70 ℃ / 150 ℃, the valve automatically closes. Manual opening or reset. | ![]() |
| Fire control valve | FHF-WS-FK | Normally open; the 70 ℃ fuse activates and the valve automatically closes. Manual opening or reset. Five-level air volume adjustment within 0–90°. Outputs a valve-closing signal; signal output optional per user requirements. | ![]() |
| Electric fire damper | FHF-WSDc-K | Manual close or reset; normally open. When airflow temperature reaches 70 ℃, the fuse activates to automatically close the valve. Outputs a valve-closing signal. | ![]() |
| Electric fire control valve | FHF-WSDc-FK | Manual close or reset; normally open. When airflow temperature reaches 70 ℃, the fuse activates to automatically close the valve. Outputs a valve-closing signal. Includes air volume adjustment function. | — |
| Fire damper | FHF-WSDc-K | Normally open; when airflow temperature reaches 70 ℃, the fuse activates to automatically close the valve. The valve can be closed via a DC24V power supply. Manual opening or reset. Outputs a valve-closing signal that can be interlocked with other devices. | — |
| Fireproof vent | FHFK-W | Can be used as an air outlet to adjust the direction of supply airflow. Normally open; when air temperature reaches 70 ℃, the valve closes under the drive of a shape memory alloy or the action of a temperature fuse. | ![]() |
| Fully automatic fire damper | FHF-WSDcDj-K | Normally open; when airflow temperature reaches 70 ℃, the fuse activates and the valve automatically closes. A DC24V signal can quickly close the valve. Manual opening or reset. After closing, the valve can be reset to the open state via a DC24V power supply. | ![]() |
|
|