NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure

Guangzhou Xingjin Fire Equipment Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure

Brand Name : XINGJIN

Model Number : Novec 1230

Certification : GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1

Place of Origin : Guangzhou,China

MOQ : 10 set system

Price : Pricing based on quantity

Payment Terms : T/T, L/C

Supply Ability : 30000set/month

Delivery Time : 15-20days

Packaging Details : Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Filling pressure : 4.2Mpa/5.6Mpa

Scale of Protective region for one zone : area:max single-zone is 800m² volume: max single-zone is 3600m³

Spraying time : ≤10s

Filling density : ≤950kg/m3,≤1080kg/m3

power : DC24V/1.6A

Nitrogen Pressure of Driving De vice : 6.0±1.0Mpa(20℃)

Condition of reserving room for container : temperature: -10~50℃, relative humidity: ≤97%

max working pressure : 5.3Mpa/8.0Mpa

min working pressure : 4.2Mpa/4.6Mpa

Contact Now

Pipe Network Type Novec 1230 Automatic Fire Suppression System

Novec 1230 fluid offers a unique combination of safety, low environmental impact, and extinguishing performance, making it the only chemical halon replacement to provide a viable, long-term, environmentally sustainable technology for special-hazard fire protection.

Applications

This system is suitable for protecting high-value and high-risk environments, including:

  • Electronic computer rooms, data processing centers, and telecommunications facilities
  • Process control rooms and expensive medical equipment
  • Industrial equipment, libraries, museums, and art galleries
  • Clean rooms and echoic chambers
  • Emergency power facilities and flammable liquid storage areas
  • Fire-prone locations such as paint-spraying production lines, aging electrical equipment, rolling machines, printing machines, oil switches, oil-immersed transformers, melt impregnating tanks, and large generators
  • Drying equipment, pulverized coal sections of cement production processes, ship engine rooms, and cargo holds
NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure
System Composition

The pipe network type Novec 1230 automatic fire suppression system is mainly composed of three parts: extinguishing devices, pipe fittings, and electrical accessories.

  • Extinguishing devices — the cylinder that fills and stores Novec 1230, the frame, and the driving device (nitrogen cylinder) that triggers the storage cylinder to discharge the agent.
  • Pipe fittings — the conduits that connect the extinguishing device and guide the agent into the protected zone, such as high-pressure galvanized steel pipe, flanges, and elbows.
  • Electrical accessories — the components used to detect and monitor the entire protected area, control the whole system, warn people to evacuate, and prevent fire expansion.

These three integrated parts work tog to efficiently detect, supervise, alarm, and extinguish fire automatically. The complete composition of the system is shown below.

NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure
Single/multiple cylinders for multiple zones
NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure
Multiple cylinders for one zone
NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure
Single cylinder for one zone
Technical Parameters
No. Specification Technical Parameter
1 Filling pressure 4.2 MPa / 5.6 MPa
2 Scale of protective region for one zone Area: max single-zone 800 m²; Volume: max single-zone 3600 m³
3 Spraying time ≤ 10 s
4 Filling density ≤ 950 kg/m³ / ≤ 1080 kg/m³
5 Power DC 24 V / 1.6 A
6 Nitrogen pressure of driving device 6.0 ± 1.0 MPa (20 °C)
7 Condition of reserving room for container Temperature: −10 to 50 °C; relative humidity: ≤ 97%
8 Max working pressure 5.3 MPa / 8.0 MPa
9 Min working pressure 4.2 MPa / 4.6 MPa

Where two values are listed, they correspond to the two available filling-pressure configurations (4.2 MPa and 5.6 MPa).

Why Choose Us
NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure

Product Tags:

Novec1230 fire suppression system with fast discharge

      

Clean agent gas fire suppression system

      

NOVEC 1230 pipe network discharge system

      
Quality NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure for sale

NOVEC 1230 Fire Suppression System Clean Agent Fire Suppression System with 10 Second Discharge Pipe Network Type and 4.2Mpa Filling Pressure Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)